Error Code: E1

Water level error

MEDIUM
Troubleshooting Steps:

Water level sensor malfunction. Check water supply and sensor.

Error Code: E2

Water pump error

HIGH
Troubleshooting Steps:

Water pump malfunction. Check pump operation and water flow.

High Priority: Professional attention recommended to prevent damage.

Error Code: E3

Fan motor error

HIGH
Troubleshooting Steps:

Fan motor malfunction. Check motor operation and remove obstructions.

High Priority: Professional attention recommended to prevent damage.

Error Code: E4

Temperature sensor error

MEDIUM
Troubleshooting Steps:

Temperature sensor malfunction. Check sensor and wiring.

Error Code: E5

Control board error

HIGH
Troubleshooting Steps:

Control board malfunction. Professional replacement may be required.

High Priority: Professional attention recommended to prevent damage.

Error Code: F1

Water overflow

MEDIUM
Troubleshooting Steps:

Water overflow detected. Check drain system and water controls.

Error Code: F2

Low water level

MEDIUM
Troubleshooting Steps:

Low water level detected. Check water supply and connections.

Error Code: F3

Pad condition error

MEDIUM
Troubleshooting Steps:

Cooling pad condition sensor error. Check pads and water distribution.

Error Code: P1

Power error

MEDIUM
Troubleshooting Steps:

Power supply abnormality. Check electrical connections and voltage.

Error Code: P2

Motor protection

HIGH
Troubleshooting Steps:

Motor protection activated. Check motor and electrical supply.

High Priority: Professional attention recommended to prevent damage.

Still Having Issues with Your Bonaire System?

Our certified technicians are experts in Bonaire air conditioning systems. We provide professional diagnosis, repair, and maintenance services across Melbourne.

Licensed Bonaire technicians
Same-day service available
Genuine parts and warranty
24/7 emergency service
Call 0405 133 761

Available 24/7 for emergencies

Error Severity Guide

CRITICALTurn off system immediately
HIGHProfessional attention needed
MEDIUMSchedule service soon
LOWMonitor and maintain

Safety First

  • Always turn off power before inspection
  • Never attempt electrical repairs yourself
  • Check for gas leaks if you smell refrigerant
  • Call professionals for critical errors
  • Regular maintenance prevents problems