Fujitsu Error Codes & Troubleshooting

Fujitsu Logo

Fujitsu Error Codes & Troubleshooting

Fujitsu air conditioners provide reliable comfort with advanced inverter technology and smart controls.

40 Error Codes Listed3 Critical Issues

Error Code: Error 01

High pressure switch

HIGH
Troubleshooting Steps:

High pressure protection activated. Check system pressures and airflow restrictions.

High Priority: Professional attention recommended to prevent damage.

Error Code: Error 02

Low pressure switch

HIGH
Troubleshooting Steps:

Low pressure protection activated. Check refrigerant levels and leaks.

High Priority: Professional attention recommended to prevent damage.

Error Code: Error 03

Compressor overcurrent

CRITICAL
Troubleshooting Steps:

Compressor drawing excessive current. Professional diagnosis required.

Critical Issue: Turn off your system immediately and contact a professional technician.

Error Code: Error 04

System malfunction

HIGH
Troubleshooting Steps:

General system fault detected. Comprehensive professional diagnosis needed.

High Priority: Professional attention recommended to prevent damage.

Error Code: Error 05

Outdoor temperature sensor

MEDIUM
Troubleshooting Steps:

Outdoor temperature sensor malfunction. Check sensor and connections.

Error Code: Error 06

Indoor temperature sensor

MEDIUM
Troubleshooting Steps:

Indoor temperature sensor error. Affects temperature control accuracy.

Error Code: Error 07

Communication error

MEDIUM
Troubleshooting Steps:

Communication fault between units. Check wiring and connections.

Error Code: Error 08

Power supply error

MEDIUM
Troubleshooting Steps:

Power supply voltage abnormality. Check electrical supply and connections.

Error Code: Error 09

Indoor coil temperature sensor

MEDIUM
Troubleshooting Steps:

Indoor heat exchanger sensor malfunction. Check sensor and wiring.

Error Code: Error 10

Outdoor coil temperature sensor

MEDIUM
Troubleshooting Steps:

Outdoor heat exchanger sensor error. Professional diagnosis required.

Error Code: Error 11

Discharge pipe temperature sensor

MEDIUM
Troubleshooting Steps:

Compressor discharge temperature sensor fault.

Error Code: Error 12

Liquid pipe temperature sensor

MEDIUM
Troubleshooting Steps:

Liquid line temperature sensor malfunction.

Error Code: Error 13

Suction pipe temperature sensor

MEDIUM
Troubleshooting Steps:

Suction line temperature sensor error.

Error Code: Error 14

Indoor fan motor error

HIGH
Troubleshooting Steps:

Indoor fan motor malfunction. Check motor and remove obstructions.

High Priority: Professional attention recommended to prevent damage.

Error Code: Error 15

Outdoor fan motor error

HIGH
Troubleshooting Steps:

Outdoor fan motor fault. Check motor operation and obstructions.

High Priority: Professional attention recommended to prevent damage.

Error Code: Error 16

Drain pump error

MEDIUM
Troubleshooting Steps:

Drain pump malfunction. Check pump operation and drainage system.

Error Code: Error 17

Float switch activated

MEDIUM
Troubleshooting Steps:

Condensate overflow protection. Check drainage system.

Error Code: Error 18

Inverter PCB error

HIGH
Troubleshooting Steps:

Inverter control board malfunction. Professional replacement required.

High Priority: Professional attention recommended to prevent damage.

Error Code: Error 19

Indoor PCB error

HIGH
Troubleshooting Steps:

Indoor unit control board fault. Professional diagnosis needed.

High Priority: Professional attention recommended to prevent damage.

Error Code: Error 20

Outdoor PCB error

HIGH
Troubleshooting Steps:

Outdoor unit control board malfunction. Professional replacement required.

High Priority: Professional attention recommended to prevent damage.

Error Code: Error 21

Compressor thermal protection

CRITICAL
Troubleshooting Steps:

Compressor overheating protection activated. Check system operation.

Critical Issue: Turn off your system immediately and contact a professional technician.

Error Code: Error 22

Freeze protection

MEDIUM
Troubleshooting Steps:

Indoor coil freeze protection. Check airflow and refrigerant levels.

Error Code: Error 23

EEV malfunction

HIGH
Troubleshooting Steps:

Electronic expansion valve error. Professional diagnosis required.

High Priority: Professional attention recommended to prevent damage.

Error Code: Error 24

4-way valve error

HIGH
Troubleshooting Steps:

Reversing valve malfunction. Check valve operation in heat pump mode.

High Priority: Professional attention recommended to prevent damage.

Error Code: Error 25

Current sensor error

MEDIUM
Troubleshooting Steps:

Current sensing circuit malfunction. Check electrical connections.

Error Code: Error 26

Inverter overload

HIGH
Troubleshooting Steps:

Inverter overload protection. Check electrical load and connections.

High Priority: Professional attention recommended to prevent damage.

Error Code: Error 27

DC voltage error

HIGH
Troubleshooting Steps:

DC bus voltage abnormality. Check power supply and inverter.

High Priority: Professional attention recommended to prevent damage.

Error Code: Error 28

Phase current error

HIGH
Troubleshooting Steps:

Phase current abnormality detected. Professional electrical diagnosis required.

High Priority: Professional attention recommended to prevent damage.

Error Code: Error 29

Defrost sensor error

MEDIUM
Troubleshooting Steps:

Defrost temperature sensor malfunction. Check sensor operation.

Error Code: Error 30

Remote controller error

LOW
Troubleshooting Steps:

Remote controller malfunction. Check batteries and replace controller if needed.

Error Code: Error 31

Filter sign

LOW
Troubleshooting Steps:

Filter cleaning reminder. Clean filter and reset indicator.

Error Code: Error 32

Refrigerant shortage

HIGH
Troubleshooting Steps:

Low refrigerant detected. Check for leaks and recharge system.

High Priority: Professional attention recommended to prevent damage.

Error Code: Error 33

Compressor locked rotor

CRITICAL
Troubleshooting Steps:

Compressor motor locked. Immediate professional attention required.

Critical Issue: Turn off your system immediately and contact a professional technician.

Error Code: Error 34

Heat sink temperature error

HIGH
Troubleshooting Steps:

Heat sink overheating. Check cooling and ventilation.

High Priority: Professional attention recommended to prevent damage.

Error Code: Error 35

Oil return operation

LOW
Troubleshooting Steps:

Oil return cycle in progress. Normal for multi-unit systems.

Error Code: Error 36

Address setting error

MEDIUM
Troubleshooting Steps:

Unit address configuration error. Check DIP switch settings.

Error Code: Error 37

Capacity mismatch

MEDIUM
Troubleshooting Steps:

Indoor and outdoor unit capacity mismatch. Check system configuration.

Error Code: Error 38

Multiple indoor units error

MEDIUM
Troubleshooting Steps:

Multi-unit system configuration error. Check unit connections and settings.

Error Code: Error 39

Power supply frequency error

MEDIUM
Troubleshooting Steps:

Power frequency abnormality. Check electrical supply stability.

Error Code: Error 40

Louver motor error

LOW
Troubleshooting Steps:

Air direction motor malfunction. Check motor and remove obstructions.

Still Having Issues with Your Fujitsu System?

Our certified technicians are experts in Fujitsu air conditioning systems. We provide professional diagnosis, repair, and maintenance services across Melbourne.

Licensed Fujitsu technicians
Same-day service available
Genuine parts and warranty
24/7 emergency service
Call 0405 133 761

Available 24/7 for emergencies

Error Severity Guide

CRITICALTurn off system immediately
HIGHProfessional attention needed
MEDIUMSchedule service soon
LOWMonitor and maintain

Safety First

  • Always turn off power before inspection
  • Never attempt electrical repairs yourself
  • Check for gas leaks if you smell refrigerant
  • Call professionals for critical errors
  • Regular maintenance prevents problems