Hitachi Error Codes & Troubleshooting

Hitachi Logo

Hitachi Error Codes & Troubleshooting

Hitachi air conditioners deliver reliable performance with advanced features for home comfort.

35 Error Codes Listed3 Critical Issues

Error Code: 01

Indoor temperature sensor error

MEDIUM
Troubleshooting Steps:

Room temperature sensor malfunction. Check sensor and wiring connections.

Error Code: 02

Indoor coil sensor error

MEDIUM
Troubleshooting Steps:

Indoor heat exchanger sensor fault. Professional replacement may be required.

Error Code: 03

Outdoor temperature sensor error

LOW
Troubleshooting Steps:

Outdoor ambient temperature sensor failure. Check sensor operation.

Error Code: 04

Outdoor coil sensor error

MEDIUM
Troubleshooting Steps:

Outdoor heat exchanger sensor malfunction. Professional diagnosis needed.

Error Code: 05

Communication error

MEDIUM
Troubleshooting Steps:

Communication fault between units. Check connecting cables and terminals.

Error Code: 06

High pressure error

HIGH
Troubleshooting Steps:

High pressure protection activated. Check system pressures and refrigerant.

High Priority: Professional attention recommended to prevent damage.

Error Code: 07

Low pressure error

HIGH
Troubleshooting Steps:

Low pressure protection activated. Check for refrigerant leaks.

High Priority: Professional attention recommended to prevent damage.

Error Code: 08

Compressor error

CRITICAL
Troubleshooting Steps:

Compressor malfunction detected. Immediate professional attention required.

Critical Issue: Turn off your system immediately and contact a professional technician.

Error Code: 09

Fan motor error

HIGH
Troubleshooting Steps:

Fan motor malfunction. Check for obstructions and motor operation.

High Priority: Professional attention recommended to prevent damage.

Error Code: 10

Power supply error

MEDIUM
Troubleshooting Steps:

Power supply voltage abnormality. Check electrical supply and connections.

Error Code: 11

Discharge temperature sensor error

MEDIUM
Troubleshooting Steps:

Compressor discharge temperature sensor fault.

Error Code: 12

Suction temperature sensor error

MEDIUM
Troubleshooting Steps:

Suction line temperature sensor malfunction.

Error Code: 13

Liquid line temperature sensor error

MEDIUM
Troubleshooting Steps:

Liquid line temperature sensor fault.

Error Code: 14

Indoor PCB error

HIGH
Troubleshooting Steps:

Indoor unit control board malfunction. Professional replacement required.

High Priority: Professional attention recommended to prevent damage.

Error Code: 15

Outdoor PCB error

HIGH
Troubleshooting Steps:

Outdoor unit control board fault. Professional diagnosis needed.

High Priority: Professional attention recommended to prevent damage.

Error Code: 16

Compressor overcurrent

CRITICAL
Troubleshooting Steps:

Compressor drawing excessive current. Professional diagnosis required.

Critical Issue: Turn off your system immediately and contact a professional technician.

Error Code: 17

Compressor locked rotor

CRITICAL
Troubleshooting Steps:

Compressor motor locked. Immediate professional attention required.

Critical Issue: Turn off your system immediately and contact a professional technician.

Error Code: 18

Indoor fan motor error

HIGH
Troubleshooting Steps:

Indoor fan motor malfunction. Check motor and remove obstructions.

High Priority: Professional attention recommended to prevent damage.

Error Code: 19

Outdoor fan motor error

HIGH
Troubleshooting Steps:

Outdoor fan motor fault. Check motor operation and obstructions.

High Priority: Professional attention recommended to prevent damage.

Error Code: 20

EEV malfunction

HIGH
Troubleshooting Steps:

Electronic expansion valve error. Professional diagnosis required.

High Priority: Professional attention recommended to prevent damage.

Error Code: 21

Freeze protection

MEDIUM
Troubleshooting Steps:

Indoor coil freeze protection. Check airflow and refrigerant levels.

Error Code: 22

Defrost sensor error

MEDIUM
Troubleshooting Steps:

Defrost temperature sensor malfunction.

Error Code: 23

Current sensor error

MEDIUM
Troubleshooting Steps:

Current sensing circuit malfunction. Check electrical connections.

Error Code: 24

Inverter overload

HIGH
Troubleshooting Steps:

Inverter overload protection. Check electrical load and connections.

High Priority: Professional attention recommended to prevent damage.

Error Code: 25

DC voltage error

HIGH
Troubleshooting Steps:

DC bus voltage abnormality. Check power supply and inverter.

High Priority: Professional attention recommended to prevent damage.

Error Code: 26

Heat sink temperature error

HIGH
Troubleshooting Steps:

Heat sink overheating. Check cooling and ventilation.

High Priority: Professional attention recommended to prevent damage.

Error Code: 27

Drain pump error

MEDIUM
Troubleshooting Steps:

Drain pump malfunction. Check pump operation and drainage system.

Error Code: 28

Float switch activated

MEDIUM
Troubleshooting Steps:

Condensate overflow protection. Check drainage system.

Error Code: 29

4-way valve error

HIGH
Troubleshooting Steps:

Reversing valve malfunction. Check valve operation.

High Priority: Professional attention recommended to prevent damage.

Error Code: 30

Filter sign

LOW
Troubleshooting Steps:

Filter cleaning reminder. Clean filter and reset indicator.

Error Code: 31

Remote controller error

LOW
Troubleshooting Steps:

Remote controller malfunction. Check batteries and connections.

Error Code: 32

Address setting error

MEDIUM
Troubleshooting Steps:

Unit address configuration error. Check settings.

Error Code: 33

Refrigerant shortage

HIGH
Troubleshooting Steps:

Low refrigerant detected. Check for leaks and recharge system.

High Priority: Professional attention recommended to prevent damage.

Error Code: 34

Oil return operation

LOW
Troubleshooting Steps:

Oil return cycle in progress. Normal for multi-unit systems.

Error Code: 35

Capacity mismatch

MEDIUM
Troubleshooting Steps:

Indoor and outdoor unit capacity mismatch. Check system configuration.

Still Having Issues with Your Hitachi System?

Our certified technicians are experts in Hitachi air conditioning systems. We provide professional diagnosis, repair, and maintenance services across Melbourne.

Licensed Hitachi technicians
Same-day service available
Genuine parts and warranty
24/7 emergency service
Call 0405 133 761

Available 24/7 for emergencies

Error Severity Guide

CRITICALTurn off system immediately
HIGHProfessional attention needed
MEDIUMSchedule service soon
LOWMonitor and maintain

Safety First

  • Always turn off power before inspection
  • Never attempt electrical repairs yourself
  • Check for gas leaks if you smell refrigerant
  • Call professionals for critical errors
  • Regular maintenance prevents problems